Micro-Coax 35ohm transformer transmission line, commonly used for RF two-way power divider construction.
|
||||||
Outer Conductor Diameter, inch (mm) | 0.141+/-0.001 (3.581+/-0.0254) | |||||
Dielectric Diameter, inch (mm) | 0.117 (2.97) | |||||
Center Conductor Diameter, inch (mm) | 0.0508+/-0.001 (1.29+/-0.0254) | |||||
Maximum Length, feet (meters) | 20 (6.1) | |||||
Minimum Inside Bend Radius, inch (mm) | 0.188 (4.775) | |||||
Weight, pounds/100 ft. (kg/100 meters) | 3.5 (5.21) | |||||
|
||||||
Impedance, ohms | 35+/-1.0 | |||||
Frequency Range GHz | DC-31 | |||||
Velocity of Propagation % | 70 | |||||
Capacitance, pF/ft. (pF/meter) | 41.5 (136) | |||||
Typical Insertion Loss, dB/ft. (dB/meter) and Average Power Handling, Watts CW at 20 degrees Celsius and Sea level |
Frequency | Insertion Loss | Power | |||
0.5 GHz 1.0 GHz 5.0 GHz 10.0 GHz 20.0 GHz |
0.09 (0.28) 0.12 (0.41) 0.30 (0.99) 0.45 (1.48) 0.69 (2.25) |
552.4 384.6 161.5 109.2 72.7 |
||||
Corona Extinction Voltage, VRMS @ 60 Hz | 1500 | |||||
Voltage Withstand, VRMS @ 60 Hz | 3000 | |||||
|
||||||
Outer Conductor Integrity Temperature, Deg Celsius | 175 | |||||
Maximum Operating Temperature, Deg Celsius | 125 | |||||
|
||||||
Outer Conductor | Copper | |||||
Dielectric | PTFE | |||||
Center Conductor | SPC |